Juno 60 Full Log
Really Nice Audio · Repair case records
Case record 001: Roland Juno-60 (serial 305451)
A fully documented repair, recorded as it happened.
This page is a structured record of one repair. It captures the diagnosis as it unfolded, including the dead ends, every decision taken, and what was kept, repaired or replaced, so that the work can be checked, repeated and learned from.
- Hands-on time
- 4 hours
- Documentation
- about 8 hours
- Diagnostic steps
- 27, including dead ends
- Interventions
- 12
- Parts
- £10
- Outcome
- Complete, everything working
The video
Video: Roland Juno 60 Repair and Demos, Really Nice Audio, 29:35. https://youtu.be/sDFHMipudyw
Chapters 29 Length 29:35
- Intro – unwanted modulation
- First look inside
- Probing the VCA outputs
- The VCA control voltage & a suspect multiplexer
- Opening up board A
- Scoping the multiplexers
- Suspecting a grounding fault
- Tracing the earth traces
- Found it: ripped-off traces
- Rewiring the earth
- Power-on test
- Fitting a backup battery holder
- Loading the factory patches from tape
- Demo
- The MIDI retrofit isn’t working
- Where is it getting its power from?
- Temperature checks
- MIDI arrives – a Groove Electronics board
- Heat sinking the regulator
- MIDI working
- Running too hot
- Swapping the 7805 for a DC-DC converter
- Adding an output cap
- Why the supply was overloaded
- Soak test
- Fixing a PAT test fault
- Sending MIDI out
- Wrap-up & a power supply warning
- Outro
The instrument
Identity and provenance
- Make
- Roland
- Model
- Juno-60
- Serial number
- 305451 LOG. Published with the owner’s permission as proof of provenance Restorer.
- Year or estimated year
- Not recorded
- Original mains voltage
- Not recorded. The rear rating plate appears in the video (27:52) but its voltage isn’t read. UK-market unit (inferred, from the UK 13A-fused mains plug and the PAT test).
- Stream
- Private client Restorer
Signs of previous repairs and modifications
- Replacement power supply. A switch-mode module on an "OCP BOARD JU-6/60" carrier (silk-screen "JU-6/60_PSU_3e"), over-current trip about 0.59 A ±5% per rail (+15 V, +5 V, −15 V), with +10 V made by a regulator IC on the OCP board LOGVIDEO 00:25–00:40, 20:50.
- Replacement CPU on Panel Board B. NMOS D8049C-028 (marked "www.vintagesynthparts.com"), same firmware code as the original µPD80C49C-028 LOG.
- Groove Electronics MIDI retrofit. Pamphlet drawings dated 15/12/85, with its function button mounted below the CHORUS OFF switch LOGGROOVE.
- Pin headers fitted at test points. VIDEO 01:12
- MIDI board power wires taped off. By the previous technician LOGVIDEO 17:44.
- A multiplexer suspected. The previous technician had suspected a multiplexer VIDEO 02:21.
- Original backup battery still fitted. With a bent leg VIDEO 00:51, 08:59.
- 13A fuse in the mains plug. LOG
What was wrong
Reported fault
A wobble on every note even with no modulation dialled in. The previous technician suspected a multiplexer. MIDI not working. VIDEO description; 02:21; 17:44
Paraphrased.
Symptoms observed on arrival
- Warbly, "FM’d" sound on every voice, present even with chorus off LOGVIDEO 00:06–00:25.
- Envelope interference with DECAY at minimum LOG.
- One voice quieter than the others LOG.
- MIDI retrofit not working, its power wires taped off LOGVIDEO 17:44.
- Patch memory almost empty LOGVIDEO 09:23.
- Mains cable loose at the rear cable entry, found during the PAT test LOGVIDEO 27:51.
- Cosmetic condition
- Not recorded
- Photos taken
- Not recorded. No photo list exists in the log. Scope photos and board photos were taken during the work inferred, but they aren’t catalogued.
The diagnostic path
The order follows the video timeline. Where the order isn’t recorded, it’s marked inferred. Each step shows what was suspected, the test, the tool, the result and the conclusion. Dead ends and wrong guesses are kept: they are part of how the fault was found.
- Main path
- Dead end or wrong guess (steps 1, 7, 16)
- Root cause found (step 13)
- The wobble on every note
1SuspectedDC offset at the C5/R14 junction (VCF input) on the even-numbered voicesConclusionDead end. Not a fault. (Position in the sequence: early, inferred)Dead end
- Test
- Voltage measurement at C5/R14
- Tool
- Not recorded
- Result
- Offset reading turned out to be a measurement error. All C5/R14/IR3109 pin 2 points correct on every voice LOG
- Patch memory
15SuspectedMemory empty because of battery or RAM powerConclusionSuspected the previous technician disconnected the RAM’s power (not confirmed)
- Test
- Checked the memory before removing the battery
- Tool
- Front panel
- Result
- Nothing much in memory VIDEO 09:23
16SuspectedTape load procedureConclusionWrong guess about the procedureWrong guess
- Test
- Loaded factory patches from a WAV, pressing LOAD before the tone
- Tool
- Logic Pro, audio interface
- Result
- Load error VIDEO 10:05
- The MIDI retrofit
21SuspectedCorrect supply for the boardConclusionNeeds about 10 V
- Test
- Identified the board as Groove Electronics; read its instructions
- Tool
- GROOVE pamphlet; owner and previous tech
- Result
- Originally fed from the bridge rectifier of the original PSU LOGGROOVEVIDEO 20:24
23SuspectedSupply capacityConclusionNot enough headroom: by the restorer’s rule of thumb a supply should have at least double the current required Restorer. (Position in the sequence: inferred)
- Test
- Observed the replacement PSU, then read the specs printed on the OCP board
- Tool
- Observation; OCP board silk-screen
- Result
- The PSU shut down a couple of times with the MIDI board connected to its 10 V. Printed limit 590 mA per rail, with no indication of which rail feeds the 10 V. Juno draws roughly 300 mA, plus 200 mA for the MIDI board, about 500 mA in total, close to the 590 mA limit Restorer
- Mains safety
26SuspectedMains cable entryConclusionRepaired
- Test
- PAT test
- Tool
- PAT tester inferred
- Result
- Fault at the cable entry; passed after the fix VIDEO 27:51LOGRestorer
- MIDI out
Faults and causes
Eight faults, F1 to F8. F1a and F1b are consequences of F1. The tag on each card is the component class.
Panel Board A: pot multiplexers and sample/holds (control voltages)
other (PCB copper earth traces)- Reference / part
- Ground path to pin 8 of both 4051 multiplexers, IC8 and IC3 (HD14051B)
- How it failed
- Earth traces ripped off on both sides of the board; open circuit
- Evidence
- Continuity OL from pin 8 to ground; identical buffered outputs; stepped CV at chorus board pin 14; visible under the microscope LOGVIDEO
- Likely cause
- Unknown. Not recorded (possibly mechanical damage or earlier rework, inferred)
Voice level (one voice)
— (consequence of F1)- Reference / part
- Not recorded which voice
- How it failed
- Quieter than the others
- Evidence
- Cured by the F1 repair LOG
- Likely cause
- Consequence of F1
Envelope (S/D control lines)
— (consequence of F1)- Reference / part
- Not recorded
- How it failed
- Interference at minimum decay
- Evidence
- Listed as cured with the earth fault LOG
- Likely cause
- Consequence of F1
MIDI retrofit power
other (wiring disconnected)MIDI retrofit power / replacement PSU +10 V rail
voltage regulator- Reference / part
- MIDI board 7805 (LM340T-5); OCP board +10 V regulator (reference not recorded)
- How it failed
- MIDI board drew about 200 mA from the replacement PSU’s +10 V regulator, which ran hot (77 °C)
- Evidence
- FLIR readings; current measurement LOGVIDEO; PSU shut down a couple of times with the MIDI board on its 10 V Restorer
- Likely cause
- Design weakness: a 1985 retrofit designed for the original unregulated rail, combined with a modern PSU not sized for it (inferred from VIDEO 25:52 and LOG)
MIDI retrofit power
electrolytic capacitor- Reference / part
- Input cap at the MIDI board regulator, 10 V-rated
- How it failed
- Under-rated for a 10 V rail; no failure recorded
- Evidence
- Rating noted LOGVIDEO 18:25
- Likely cause
- Design weakness inferred
MIDI retrofit power
other (missing part)- Reference / part
- Regulator output decoupling cap
- How it failed
- Not fitted originally
- Evidence
- Datasheet calls for one VIDEO 23:27
- Likely cause
- Design weakness
Patch memory
Not recordedMains input
mechanical- Reference / part
- Mains cable at the rear entry
- How it failed
- Cable not pulled through or clamped tightly
- Evidence
- Found in the PAT test LOGVIDEO 27:51
- Likely cause
- Unknown
Mains plug
other (fuse rating)- Reference / part
- Plug fuse 13 A
- How it failed
- Over-rated fuse
- Evidence
- LOG
- Likely cause
- Unknown. Not recorded who fitted it.
The decision record
Twelve interventions, I1 to I12. Each card shows what was done, whether it can be undone, and whether the original part was kept, followed by the alternatives that were considered and the reasons.
- Fully reversible
- Partly reversible
- n/a or not recorded
Panel Board A earth
- Actionrepair
- ReversiblePartly inferred
- Original keptn/a
- Original part removed
- None (traces damaged)
- Replacement
- Two wire links LOGVIDEO 06:41
- Why
- "A good solid connection"; didn’t want to scrape and bridge the traces VIDEO
- Alternatives considered
- Trace repair (scrape and bridge): rejected VIDEO
- Historical evidence lost
- Not recorded
4051 multiplexers IC8 and IC3
- Actionkeep
- Reversiblen/a
- Original keptn/a
- Original part removed
- —
- Replacement
- —
- Why
- Chips not faulty once grounded VIDEO "points to double-check" 7
- Alternatives considered
- Replacing IC8, which the previous technician suspected: not pursued inferred
- Historical evidence lost
- None
Backup battery
- Actionsubstitute
- ReversiblePartly inferred
- Original keptYes, kept by RNA in labelled bags Restorer
Patch memory
- Actionother (reload)
- ReversibleNot recorded
- Original keptNot recorded (no dump of the previous contents recorded)
- Original part removed
- Previous memory contents (almost empty)
- Replacement
- Factory A/B patch WAVs from presetpatch.com, loaded through tape LOAD LOG
- Why
- Memory empty
- Alternatives considered
- Not recorded
- Historical evidence lost
- Any remaining previous patches inferred
MIDI board power connection
- Actionrepair (reconnect)
- ReversibleFully inferred
- Original keptn/a
- Original part removed
- —
- Replacement
- Leads to the OCP board +10 V (at a diode) and GND LOGVIDEO 20:40
- Why
- Board needs about 10 V GROOVEVIDEO
- Alternatives considered
- Hooking to a nearby 5 V point was first considered VIDEO 18:00; rejected because the 5 V rail lacked headroom for the extra 200 mA Restorer
- Historical evidence lost
- Original connection point to the original PSU’s bridge rectifier: no witness marks found VIDEO 19:32
OCP board +10 V regulator
- Actionother (add heatsink)
- ReversibleFully inferred
- Original keptn/a
MIDI board regulator
- Actionsubstitute
- ReversibleFully (inferred: pin-compatible)
- Original keptYes, kept by RNA in labelled bags Restorer
- Original part removed
- 7805 / LM340T-5 (maker and date code not recorded in the log)
- Replacement
- Recom R-78E5.0-0.5 switching regulator, 7–28 V in, 5 V 500 mA, 7805 pinout; RS 757-7239 LOG
- Alternatives considered
- Not recorded in the log
- Historical evidence lost
- Not recorded
MIDI board input cap
- Actionreplace
- ReversibleFully inferred
- Original keptYes, kept by RNA in labelled bags Restorer
- Original part removed
- Original 10 V-rated cap (value, maker and date code not recorded)
- Replacement
- 10 µF 35 V LOG
- Why
- Under-rated for a 10 V rail; datasheet calls for 10 µF LOGVIDEO 23:27
- Alternatives considered
- Not recorded
- Historical evidence lost
- Not recorded
MIDI board output cap
- Actionother (add)
- ReversibleFully inferred
- Original keptn/a
- Original part removed
- —
- Replacement
- 10 µF 35 V Panasonic between the existing regulator output and earth holes LOGVIDEO 24:56
- Why
- Required by the Recom datasheet; none fitted LOG
- Alternatives considered
- Not recorded
- Historical evidence lost
- None
Mains cable entry
- Actionrepair
- ReversibleFully
- Original keptn/a
- Original part removed
- —
- Replacement
- Cable pulled through and clamp retightened LOG
- Why
- PAT test finding
- Alternatives considered
- Not recorded
- Historical evidence lost
- None
Mains plug fuse
- Actionsubstitute
- ReversibleFully
- Original keptYes, kept by RNA in labelled bags Restorer
- Original part removed
- 13 A fuse
- Replacement
- 3 A fuse LOG
- Why
- Rating appropriate to the instrument inferred
- Alternatives considered
- Not recorded
- Historical evidence lost
- None
VCA gain trim (VR4)
- Actionkeep (no adjustment)
- Reversiblen/a
- Original keptn/a
- Original part removed
- —
- Replacement
- —
- Why
- Quieter voice cured by the earth repair LOG
- Alternatives considered
- VR4 trim (service notes adjustment 5-1): not needed
- Historical evidence lost
- None
Testing: before and after
| Test | Before | After | Source |
|---|---|---|---|
| Continuity, 4051 pin 8 to ground | OL (open) | Continuity on both 4051s | VIDEO 04:51, 07:04LOG |
| Chorus board pin 14 control voltage | Stepped and noisy | Not recorded (no after measurement recorded) | VIDEOLOG |
| Listening test (wobble) | Wobble on every note | "Sounds good"; everything working | VIDEO 07:34LOG |
| Voice levels | One voice quieter | Cured | LOG |
| Patch save/recall with the new battery holder | — | Patches saved and recalled | VIDEO 08:43–08:52 |
| Factory patch load | Load error (LOAD pressed too early) | Load completed | VIDEO 10:05–11:09 |
| MIDI board bench test | — | 8.00 V in, 5 V out, 0.193 A; clock pin 37; data activity; opto output OK | LOGVIDEO |
| +10 V regulator temperature | >70 °C LOG; 77.0 °C after about 1 hour VIDEO 22:48 | About 60 °C after 2 hours, lid shut LOG | LOGVIDEO |
| Soak test | — | Several hours with MIDI streaming from Logic; hotspots 58.5–64.1 °C; DC-DC converter about 34 °C (spoken); MC6802 about 63–64 °C | VIDEO 26:50–27:42LOG |
| MIDI board 5 V supply | — | 5 V confirmed | VIDEO 26:26 |
| MIDI IN | Not working | Working | LOGVIDEO 22:17 |
| MIDI OUT | — | Working in MASTER mode (function button + B) | LOGVIDEO 28:19 |
| PAT test | Fault at the mains cable entry | Passed after the cable fix Restorer | LOGVIDEO |
| Calibration | None performed. VR4 / service notes adjustment 5-1 judged unnecessary | — | LOG |
| Final sign-off | "STATUS: COMPLETE, everything working, no open items" (30 Oct 2026) | — | LOG |
Outcome
Final status
Complete. Everything working, no open items LOG.
- Remaining issues
- None recorded LOG.
- Advice given to the owner
- Not recorded as given to the owner.
Advice in the video, for viewers
Likely future failures
- The CR2032 backup cell will need replacing in time inferred.
- The MC6802 on the MIDI board runs at about 63–64 °C, which may age it and nearby parts inferred.
- The OCP board’s +10 V regulator still runs at about 60 °C (inferred risk).
- The wire-linked earth repair on Panel Board A is the known weak area if the board is flexed inferred.
Time and cost
- Total time (all stages)
- About 12 hours: 4 hours hands-on (diagnosis, repair and testing) plus about 8 hours of filming, editing and documenting Restorer. Unattended soak testing is not counted Restorer.
- Diagnosis time
- Not recorded separately; part of the 4 hours hands-on Restorer
- Repair time
- Not recorded separately; part of the 4 hours hands-on Restorer
- Testing time
- Not recorded separately; part of the 4 hours hands-on Restorer. The soak test (a couple of hours, then "hours" VIDEO 26:59–27:22) was unattended and is not counted Restorer.
- Documentation: writing the log
- Not recorded separately; within the 8 hours of filming, editing and documenting. Typed as the work went Restorer.
- Documentation: filming
- Not recorded separately; within the 8 hours Restorer
- Documentation: editing
- Not recorded separately; within the 8 hours Restorer. Finished video length is 29:35 VIDEO.
- Parts cost
- £10 Restorer. Parts: Recom R-78E5.0-0.5 (RS 757-7239), 2 × 10 µF 35 V capacitors, coin-cell holder and CR2032, heatsink, 3 A fuse, hook-up wire.
- Did documenting slow the repair?
- Typing the log as the work went felt comfortable and did not noticeably slow the repair. Most of the documentation time went on filming and editing Restorer.
Knowledge that is hard to write down
Much of a restorer’s skill lives in judgement, rules of thumb and the senses rather than in measurements. This part of the record tries to capture it, and is explicit about what it could not.
Where experience or instinct outweighed measurement
- Two buffered outputs that "shouldn’t" be identical led straight to "some kind of grounding issue", before any ground measurement was taken VIDEO 04:13–04:22.
- Choosing to remove Panel Board A and work "top down" as quicker than reverse-engineering from the other side VIDEO 02:51.
- Choosing wire links over trace repair for "a good solid connection" VIDEO 06:37.
- Choosing a DC-DC converter "because it’s only running digital anyway" VIDEO 22:50.
- Rule of thumb that a supply should have at least double the current required: about 500 mA drawn against a 590 mA limit, after the PSU shut down a couple of times, was judged too close Restorer.
Sensory cues
- SoundThe wobble heard on a held note VIDEO 00:19; "that sounds good" at power-on VIDEO 07:34; the tape data heard during loading VIDEO 10:45.
- Feel and sightThe damaged trace area "actually moving" when prodded VIDEO 06:20.
- HeatMeasured with the FLIR, not by touch VIDEO.
- SmellNot recorded.
- Things found hard to record, or not recorded
- Not recorded.
- How documenting changed the way of working
- Not recorded.
What to tell another restorer facing the same fault
- If separately held sample-and-hold outputs look identical, check the multiplexer’s ground (4051 pin 8) for continuity before replacing chips (inferred from the case).
- Press LOAD just after the leader tone starts LOG.
- A newer replacement PSU may not supply an older MIDI retrofit VIDEO 28:43.
- Be careful with the battery holder fit VIDEO 09:18.
Log, video, and neither
The repair was documented two ways at once: a written log typed as the work went, and a filmed video. Comparing them shows what each method captures, and what slips through both.
Only the log captured
- The serial number (305451)
- The dead end: DC offset at C5/R14 that turned out to be a measurement error
- The replacement CPU (D8049C-028) on Panel Board B
- The OCP board’s silk-screen version (JU-6/60_PSU_3e) and trip ratings in writing (the label appears on screen)
- The MIDI board details: EPROM "ju-6/v3.65", 74HC logic, SN74LS04, TIL111 part number, DCB mini-con wiring, full mode and operation summary
- The Recom exact part number (R-78E5.0-0.5) and RS stock number
- The input cap now 10 µF 35 V (the video calls it "the original cap")
- The quieter voice cured by the earth repair
- The envelope interference at minimum decay
- The mains plug fuse change from 13 A to 3 A
- The backup battery circuit details (D26/D27/C15, test points, below 2.5 V means memory loss)
- The original PSU architecture (service notes p12)
- The source URLs for the factory patches
Only the video captured
- The previous technician’s suspicion of a multiplexer
- Test-point pin headers fitted
- The full scope sequence: VCA outputs, chorus board in/out, IC3 versus IC8 comparison, INH check, A/B versus outputs capture
- Rail measurement at a ground point
- The printed layout with highlighted earth traces
- Microscope view of the damage
- Power-on test of Panel Board A on the bench
- Patch save/recall test
- First tape load error
- The demo section
- An initial idea to hook the MIDI board to a nearby 5 V point
- No witness marks found
- FLIR readings at each stage (including 77.0 °C)
- The heatsink cut down from a larger one
- The soak test with MIDI streaming from Logic
- The warning about newer PSUs and older MIDI retrofits
Neither captured
- The replacement PSU shutting down a couple of times with the MIDI board on its 10 V
- Reading the OCP board’s printed 590 mA limit
- The "double the current" rule of thumb and the roughly 300 mA + 200 mA estimate
Recorded here only because the restorer supplied it directly Restorer.
Which captures the diagnostic reasoning better? Assessment, not a recorded fact
Each captures a different part.
The video is better at in-the-moment reasoning. It shows the identical outputs prompting the ground suspicion (04:13), the decision to trace the earth on a printed layout (05:04), and the wrong guess about tape-load timing being corrected (10:05–10:18).
The log is better at explaining causes and decisions. It explains why a floating multiplexer ground produced stepped control voltages, the warble, the envelope noise and the quiet voice. It records part numbers and current figures behind the regulator swap, and keeps the C5/R14 dead end, which the video leaves out.
Neither records timings, photos, or the alternatives considered in detail.
Tools, sources and the role of AI
Equipment VIDEOLOG
- Rigol DS1054Z 4-channel oscilloscope, plus a second Rigol scope
- Fluke multimeter
- FLIR thermal camera
- Bench power supply with V/A/W display
- Hot-air rework station
- Microscope and magnifier lamp
- Logic Pro on a Mac with an audio interface
- Genelec monitors
- PAT tester inferred
Documents consulted
- Roland Juno-60 Service Notes, First Edition, 10 April 1983 SN: chorus board, panel board, CPU board and power supply schematics; adjustment procedures
- Printed Panel Board A copper layout, earth traces highlighted VIDEO 05:04
- Groove Electronics Juno 6/60 MIDI Interface pamphlet GROOVE
- Recom R-78E-0.5 datasheet VIDEO 23:08
- RS Components listing, stock no. 757-7239 LOG
- Factory patch WAVs from presetpatch.com LOG
Pages, diagrams and images from the Roland service notes and the Groove Electronics pamphlet are not reproduced here. They are cited as sources only.
- Forums and earlier videos
- Not recorded.
The role of AI
Mainly routine reference lookups, such as which pin carries the clock, not diagnostic answers Restorer. Some AI-suggested hypotheses were tested and ruled out:
- Leakage through C5 or across the board at the VCF input (the offset was a measurement error)
- A polarity-inversion tip for loading patches from WAV (couldn’t be sourced; pressing LOAD after the leader tone was the actual fix)
- An "IC3 INH fault", read from a capture taken on the wrong probe pin
- Suspected scope-ground artefacts
About this record
How the record was made
This record was prepared on 30 October 2026 from the sources below and no others. The repair log was typed as the work went; the video analysis was prepared from YouTube metadata, automatic captions and about 80 sampled frames. The order follows the video timeline. Where the order isn’t recorded, it’s marked inferred.
Source badges
- LOG
- Juno-60 repair log, written as the work went (final version).
- VIDEO
- Analysis of the repair video https://youtu.be/sDFHMipudyw (prepared 30 Oct 2026 from YouTube metadata, automatic captions and about 80 sampled frames). Times are mm:ss into the video.
- SN
- Roland Juno-60 Service Notes, First Edition, 10 April 1983.
- GROOVE
- Groove Electronics "Juno 6/60 MIDI Interface" installation and operation pamphlet.
- Restorer
- Details supplied directly by the restorer on 30 Oct 2026.
Honesty conventions
- Not recorded
- The sources don’t say. Gaps are shown rather than filled.
- inferred
- A conclusion drawn from the sources rather than read directly.
Consent and anonymity
- Owner consent to publication
- Yes, the owner has consented Restorer
- Named or anonymous
- Anonymous: the case corrects a previous technician’s work Restorer. Neither the owner nor the previous technician is identifiable. The serial number (305451) is published with the owner’s permission, as proof of provenance Restorer.
Record details
- Record
- Case record 001
- Date prepared
- 30 October 2026
- Version
- 1.0
- Permanent identifier (DOI)
- To be assigned
- Machine-readable copy
- Download the record as JSON
Fields marked Not recorded (22)
Numbers refer to the parts of the original record.
- 1 – Year or estimated year
- 1 – Original mains voltage
- 2 – Cosmetic condition
- 2 – Photos taken (list)
- 3 – Tool used for the C5/R14 measurement (step 1)
- 4 – Cause of the ripped earth traces (F1)
- 4 – Which voice was quieter (F1a); envelope line references (F1b)
- 4 – Component class and cause for the empty memory (F6); backup battery voltage on arrival
- 4 – Reference of the OCP board +10 V regulator (F3)
- 4 – Cause of the loose mains cable (F7) and who fitted the 13 A fuse (F8)
- 5 – Maker, value and date codes of the removed parts: original battery, 7805, 10 V input cap
- 5 – Historical evidence lost (earth repair, regulator swap, caps)
- 5 – Alternatives considered for the battery, patch reload, heatsink, regulator, caps and fuse
- 5 – Whether the previous memory contents were dumped before reloading
- 6 – Chorus board pin 14 control voltage after the repair
- 7 – Advice actually given to the owner
- 8 – Split of the 4 hands-on hours (diagnosis, repair, testing) and of the 8 documentation hours (log, filming, editing)
- 9 – Forums and earlier videos consulted
- Part 2 – Smell
- Part 2 – Things found hard to record, or chosen not to record
- Part 2 – How documenting changed the way of working
- Part 4 – Commercially sensitive material
Fields marked inferred (16)
- 1 – UK-market unit
- 2 – Photos were taken but not catalogued
- 3 – Step 1 positioned early in the sequence
- 3 – PAT tester used (step 26)
- 4 – F1 possibly mechanical damage or earlier rework
- 4 – F3 design-weakness explanation
- 4 – F4 design-weakness cause
- 5 – Reversibility of I1, I3, I5, I6, I7, I8, I9
- 5 – Replacing IC8 not pursued (I2)
- 5 – Historical evidence lost: original battery and its solder joints (I3); previous patches (I4)
- 5 – Heatsink loses no historical evidence (I6)
- 5 – Reason for the 3 A fuse (I11)
- 7 – All four "likely future failures"
- Part 2 – Advice on checking 4051 pin 8 before replacing chips
- Part 3 – Which record captures the reasoning better (an assessment)
- 3 – Position of step 23 (PSU shutdowns) in the sequence